Capacitive approach to determine phospholipase A2 activity towards artificial and natural substrates

  • A capacitive approach has been employed to develop a novel method to determine phospholipase activity. The sensing electrodes have a structure like Au/S(CH₂)₁₇CH₃/substrate/electrolyte. Hydrolysis of the substrate, mediated by phospholipase A₂, leads to the formation of water-soluble products from the insoluble substrate. This results in desorption of these products into aqueous phase and corresponding increase of the electrode capacitance. The requirement of high water solubility of the reaction products can be achieved in two ways. In the first, short-chain phospholipids are used as the substrate, in which case, water-soluble products are formed and no additional reagents are required to promote desorption of these products. The sensors prepared by this strategy provide sensitive qualitative detection of phospholipases. The second way is based on the use of a water-soluble acceptor (for example, β-cyclodextrin) to solubilize the products of hydrolysis. It allows semiquantitative detection of phospholipase activity toward long-chainA capacitive approach has been employed to develop a novel method to determine phospholipase activity. The sensing electrodes have a structure like Au/S(CH₂)₁₇CH₃/substrate/electrolyte. Hydrolysis of the substrate, mediated by phospholipase A₂, leads to the formation of water-soluble products from the insoluble substrate. This results in desorption of these products into aqueous phase and corresponding increase of the electrode capacitance. The requirement of high water solubility of the reaction products can be achieved in two ways. In the first, short-chain phospholipids are used as the substrate, in which case, water-soluble products are formed and no additional reagents are required to promote desorption of these products. The sensors prepared by this strategy provide sensitive qualitative detection of phospholipases. The second way is based on the use of a water-soluble acceptor (for example, β-cyclodextrin) to solubilize the products of hydrolysis. It allows semiquantitative detection of phospholipase activity toward long-chain natural substrates. The reaction kinetics for this case was found to be monoexponential and linearly dependent on the phospholipase concentration. The detection limit of this method, as tested with phospholipase A₂ from bee venom and soy bean lecithin as the substrate, is ∼0.5 ng/mL (500 μunits/mL).show moreshow less

Export metadata

Additional Services

Search Google Scholar
Metadaten
Author: Vladimir M. MirskyORCiDGND, Markus Mass, Christian Krause, Otto S. WolfbeisGND
DOI:https://doi.org/10.1021/ac980102w
ISSN:0003-2700
ISSN:1520-6882
Title of the source (English):Analytical Chemistry
Document Type:Scientific journal article peer-reviewed
Language:English
Year of publication:1998
Volume/Year:70
Issue number:17
First Page:3674
Last Page:3678
Faculty/Chair:Fakultät 2 Umwelt und Naturwissenschaften / FG Nanobiotechnologie
Einverstanden ✔